Removing
1. The sensor is screwed into the intake manifold on models E4 and E6 (except C16 NZ2) and in the thermostat housing on models C16 NZ2, 1.8 and 2.0 l (see illustrations).
2. Partially drain the cooling system as described in Chapter 2, to minimize coolant loss.
3. Disconnect the negative cable from the battery.
4. Disconnect the electrical wiring from the sensor, then unscrew the sensor.
Installation
5. Installation is carried out in the reverse order, paying attention to the following.
6. Coat the sensor threads with sealant before installation.
7. Fill the cooling system as described in Chapter 4.
8. Finally, start the engine and check the operation of the temperature gauge. Also check the cooling system for leaks.